Project Description
Product Features:
Calculation volume: active power, reactive power, frequency, positive sequence, negative sequence, zero sequence, vector sum (difference) and phase angle, etc., and the generated calculation volume is displayed in real time;
The electrical test of the general start-up of the generator: the generator characteristic test can be completed, including the generator no-load test, generator short-circuit test, main excitation no-load, load test, etc.; excitation test, including zero-start boost test and de-excitation test , 10% step test, etc.; concurrent test; other tests required by users.
Using advanced industrial control kernel, combined with embedded operating system, users can easily perform operations such as data storage, backup, analysis, and output.
The portable fault recorder is based on the structure of an industrial portable computer. It uses high-performance DSP, high-precision ADC chip, and embedded operating system as the hardware and software architecture. It integrates data acquisition, processing, transmission, storage, analysis and other functions. All-in-one portable device. It also belongs to digital fault recorder.
The DSP acquisition chip performs data acquisition and calculation, so as to achieve full digital analog signal filtering. The flexible and diverse sampling frequency can be selected by users from 10K/s, 20K/s, 50K/s, and 100K/s, which can be used for transient electrical signals. Waveform recording and analysis.
The portable fault recorder is an intelligent instrument that integrates the functions of fault recorder and generator characteristic test. It is favored by the majority of users due to its small size, strong functions, wide application range, flexible configuration and many other advantages. Practical tools for electric power workers, which will make due contributions to the production and technological progress of the electric power industry.
Product name | Specifications |
---|---|
Chassis | Portable industrial control case |
operating system | Embedded WindowsXP |
Display screen | 15.6"LCD display |
Resolution: 1366×768 | |
storage | 120GB solid state drive |
interface | 1 LAN interface |
2 USB | |
Keyboard, mouse | 88-key keyboard, touchpad |
Power supply | AC85-260V 50Hz±0.5Hz |
DC110-370V | |
Chassis size (width × depth × height) | 407*307*150(mm) |
Instrument weight | 10kg |
16 analog channel characteristics | |
---|---|
Channel isolation withstand voltage | 1500VDC |
A/D resolution: | 16 bits |
Valid value accuracy: | 0.20% |
Analog sampling frequency: | 10K/s, 20K/s, 50K/s, 100K/s optional |
There are 8 analog signal processing modules in total, and each module consists of 2 analog channels. The channel configuration is as follows: | |
AC voltage AC150V 3 way | Internal resistance> 80kΩ |
AC current clamp AC10A 3 way | Internal resistance <0.1Ω |
AC current AC10A 2 way | Internal resistance <0.1Ω |
AC voltage AC500V 3 way | Internal resistance> 80kΩ |
AC current clamp AC100A 1 way | Internal resistance <0.1Ω |
DC voltage DC±2000V 1 way | Internal resistance> 1MΩ |
DC voltage DC±32V 1 way | Internal resistance> 15kΩ |
DC voltage DC±100mV 1 way | Internal resistance> 8kΩ |
DC current DC4-20mA 1 way | Internal resistance 120Ω |
1. Features of 16 switching channels | |
Switch event resolution: | 0.1ms |
Standard configuration: 8 passive nodes and 8 active nodes (active node external voltage: DC24V-220V). | |
2. Failure start method | |
Analog quantity: | Sudden change, overdose, underdose |
Switch: | Displacement (closed, open) |