Project Description

Product Features:

  • The frequency response method uses the sweep frequency method to measure the winding characteristics of the transformer. Without hanging the cover and disassembling the transformer, by detecting the amplitude-frequency response characteristics of each winding, for transformers of 6kV and above, the winding distortion, bulging or shifting can be accurately measured. Deformation conditions

  • Frequency response method has very high frequency accuracy, with an accuracy higher than 0.001%

  • The frequency response method adopts digital frequency synthesis, and the frequency stability is higher.The frequency response method uses 5000V voltage isolation to fully protect the safety of the test computer.

  • The instrument has the function of measuring inductance.

Transformer winding deformation comprehensive tester (frequency response method) is used to test 6kV and above power transformers and other special-purpose transformers.Our products belong to transformer testing instruments. Power transformers are inevitably subjected to various fault short-circuit currents or physical impacts during operation or transportation.

Impact, under the action of the strong electromotive force generated by the short-circuit current, the transformer windings may lose stability, resulting in permanent deformation such as local distortion, bulging or displacement, which will seriously affect the safe operation of the transformer.

According to the national power industry standard DL/T911-2016, the frequency response analysis method is used to measure the winding deformation of the transformer, which is to detect the amplitude-frequency response characteristics of each winding of the transformer, and compare the detection results longitudinally or laterally, according to the change of the amplitude-frequency response characteristics To determine the possible deformation of the transformer winding.

The short-circuit impedance method does not require an external power supply and uses AC220V low-voltage power supply, which can automatically apply voltage to the AB, BC, and CA high-voltage windings of the transformer, collect data synchronously, and automatically calculate the impedance error percentage. The test results are very intuitive.

The short-circuit impedance method is suitable for impedance testing of transformers of any size and capacity.
During the short-circuit impedance method test, the waveform diagram of the test current and test voltage is displayed, which is convenient for real-time monitoring of the test situation.

The instrument has the function of measuring inductance.

Using windows platform, compatible with Window 2000/Window XP/Windows7/windows8.

Measuring speed:Single-phase winding 1 minute to 2 minutes
The output voltage:Vpp-25V, automatically adjusted during testing
Output impedance:50Ω
input resistance:1MΩ (Built-in 50Ω matching resistance in response channel)
Sweep frequency range:10Hz-2MHz
Frequency accuracy:0.00%
Sweep mode:Linear or logarithmic, sweep interval and number of points can be set arbitrarily
Curve display:Amplitude-frequency curve
Wide measurement dynamic range:-120dB~20dB
Impedance method to measure voltage:0~220V
Impedance method to measure current:0~10A
Impedance method frequency:50Hz/60Hz
Two-in-one host weight:7.7 kg
Two-in-one host volume:320mm*258mm*180mm