Project Description
Product Features:
The LT-800 high-voltage wireless phase nuclear instrument (hereinafter referred to as the “instrument”) is used to detect whether the power supplies on both sides of the circuit breaker in the loop network or dual power supply power network are in phase. The core phase operation must be performed before the two power supplies in the closed loop, otherwise a short circuit may occur. The instrument is suitable for the live nuclear phase operation of 6KV~220KV transmission lines, and has the functions of high-voltage electrical inspection and phase sequence verification.
The LT-800 high-voltage wireless phase phasor adopts wireless transmission technology, which is safe and reliable in operation and convenient to use. It overcomes many shortcomings of wired phase phasor and complies with the relevant national electrical safety equipment quality supervision, inspection and testing standards.
The LT-800 high-voltage wireless phase phasor adopts wireless transmission technology, high voltage wireless nuclear phaser.which is safe and reliable in operation and convenient to use. It overcomes many shortcomings of wired phase phasor and complies with the relevant national electrical safety equipment quality supervision, inspection and testing standards. Compared with the wired phase nuclear device, its main advantage is that it removes the leads connecting the two power grids (power), and its use is not restricted by any terrain and facility structure, which improves safety.
working principle
LT-800 high-voltage wireless nuclear phase instrument is composed of X transmitter, Y transmitter and receiving host. Two detection transmitters can determine whether the line is live, and then send out the measured phase and frequency signals. The receiving host receives the signals sent back by the two detecting and transmitting devices, thereby judging whether the two lines are in phase.
1. Phase difference accuracy: error ≤5°; |
---|
2. Self-calibration error: <2°; |
3. Frequency accuracy: ±0.1HZ; |
4. The voltage level measured by this product is 6KV-500KV; |
5. The transmission distance between the transmitter and the receiving host is greater than 130 meters, and the maximum distance between the two transmitters is about 260 meters; |
6. The result judgment (in-phase and out-of-phase) adopts the A-level standard, the phase difference ≥30° is out-of-phase, and the phase difference <30° is in-phase; |
7. Real-person voice prompts, male voices "in phase", female voices "please pay attention to different phases"; |
8. The screen displays the phase difference, frequency, waveform and displacement diagram of the two lines at the same time; |
9. The host displays the battery level and automatically shuts down if there is no operation for half an hour; |
10. Both transmitters and receivers have built-in rechargeable lithium batteries; |
11. It has the functions of high-voltage electrical inspection and phase sequence verification; |
12. Leakage current during high voltage measurement <10uA; |
13. The working power consumption of the transmitter is less than 0.1W, and the working power consumption of the receiving host is less than 0.3W; |
14. The host lithium battery capacity is about 2200mAH, and the transmitter battery capacity is about 350mAH; |
15. If the instrument is used 10 times a year, each time is 30 minutes, the charging cycle is about 1 year; |
16. Working environment: -35℃--- +45℃ humidity ≤95%RH; |
17. Storage environment: -40℃--- +55℃ humidity ≤95%RH; |
18. The weight of the whole machine: about 4.5KG; |
19. Instrument packaging size: length 71cm*width 26cmm*height 11cm. |
Item Name | Quantity |
---|---|
Aluminum alloy case | 1 piece |
Receiving host | 1 piece |
launcher | 2 pcs |
Telescopic insulating rod (3 meters) | 2 pieces |
charger | 2 pcs |
Tip terminal | 2 pcs |
Test line (built-in resistance) | 2 pieces |
Manual | 1 set |
factory inspection report | 1 set |
Product certification | 1 set |