LTZR-100A DC resistance tester test and operation method

Home/News/LTZR-100A DC resistance tester test and operation method

LTZR-100A DC resistance tester test and operation method

Your Content Goes Here

The DC resistance test developed by Litai Power can check the welding quality of the winding joints and whether the windings have inter-turn short circuits. It can detect whether the contacts of the voltage tap changer are in good contact and whether the actual position of the tap changer matches the indicated position. Whether the wire is broken, whether there are broken strands in the multi-strand wire winding, etc. What customers want to know most is the test and operation method of the DC resistance tester. The following takes the LTZR-100A DC resistance tester test and operation method as an example:
1. Test wiring of the DC resistance tester: Connect the tested product firmly to the terminal of the machine through the special test line, and connect the ground wire at the same time.
A. Direct measurement wiring, see Figure 2:

B. The wiring of the assisted magnetic method is shown in Figures 3 to 5 (applicable to Y(N)-d-11 connection group).
When measuring the low-voltage side of a large-capacity transformer, if the maximum current of the DC resistance tester is relatively small under existing conditions, or in order to speed up the measurement, you can choose the magnetic method to measure. In the following figure, Figure 3, Figure 4, Figure 5 are the wiring methods for measuring low voltage Rac, Rba, and Rcb respectively

2. Current selection: Turn on the power switch (I on the switch is on, O is off) and all current values will be displayed on the display. At this time, the preset current of the tested product can be selected through the selection key, and each time the selection key is pressed , The cursor will scroll between the current values of 10A, 20A, 40A, and 100A.
3. Test: When the current is selected, press the confirm key to start the test, and the meter will indicate the selected current value at the same time. After pressing the confirm button, the display shows “Charging”, and after a few seconds, it shows “Testing”, which means that the charging is complete. Enter the test state, a few seconds later, the measured resistance will be displayed.
4. After the test is completed, press the reset button, the power supply of the instrument will be disconnected from the winding, and the instrument will be discharged at the same time, the sound will alarm, and the ammeter will return to the zero position. At this time, the display screen returns to the initial state. After the second measurement or turn off the power supply, remove the test wire and the power wire to end the measurement.

Since the date of purchase of our company’s DC resistance tester, there will be technical personnel and video training on the test and operation methods of the DC resistance tester. Our company provides lifetime warranty and technical services for the whole machine. If you find any abnormalities or malfunctions in the DC resistance tester, please contact our company in time to arrange the most convenient solution for you.

By litaitester|2021-04-21T14:09:11+08:00August 15th, 2018|News|0 Comments

Share This Story, Choose Your Platform!

FacebookTwitterRedditLinkedInWhatsAppTumblrPinterestVkEmail

Related Posts

  • How to set the delay of the microcomputer relay protection tester
    How to set the delay of the microcomputer relay protection tester
    Gallery

    How to set the delay of the microcomputer relay protection tester

  • Operating precautions for LTDSY-VI cable identification instrument
    Operating precautions for LTDSY-VI cable identification instrument
    Gallery

    Operating precautions for LTDSY-VI cable identification instrument

  • Working principle of single-phase ground fault locator for overhead line
    Working principle of single-phase ground fault locator for overhead line
    Gallery

    Working principle of single-phase ground fault locator for overhead line

  • Test method of clamp ground resistance tester
    Test method of clamp ground resistance tester
    Gallery

    Test method of clamp ground resistance tester

  • What are the four major components of the multi-frequency induction withstand voltage tester
    What are the four major components of the multi-frequency induction withstand voltage tester
    Gallery

    What are the four major components of the multi-frequency induction withstand voltage tester

Case

Recent Posts

  • Betsson Guía Completa para Descargar la App y Disfrutar de tus Apuestas_8
  • Gamble Real money Online Black-jack from the Better Casinos
  • Gamble On the web Blackjack the real deal Currency at the best United states Gambling enterprises Updated 2025
  • Gamble Real money Online Black-jack from the Better Casinos
  • How online Casino Games Work As A Business Model

Contact Info

  • Wuhan Litai Electric Power New Technology Co., Ltd.

  • Room 2112, Xike Building, Shuangheng Pioneer Park, No.312, Luoyu Road, Hongshan District, Wuhan, Hubei,China.

  • +86 189-6395-7094
  • manager@litaitester.com
  • Monday - Friday: 8:00 AM - 10:00 PM

Recent Posts

  • Betsson Guía Completa para Descargar la App y Disfrutar de tus Apuestas_8
  • Gamble Real money Online Black-jack from the Better Casinos
  • Gamble On the web Blackjack the real deal Currency at the best United states Gambling enterprises Updated 2025
  • Gamble Real money Online Black-jack from the Better Casinos
  • How online Casino Games Work As A Business Model
  • Play Live Roulette Free: A Helpful and Beneficial Overview

Products

  • Withstand Voltage Test Series
  • SF6 Gas Detection Series
  • Relay Protection Test Series
  • Insulation Grounding Test Series
  • Current Transformer Test Series
  • Circuit Breaker Circuit Test Series
  • Cable High Voltage Pulse Series
  • Battery Series

Recent Works

Copyright 2012 - 2021 LiTaiTester | All Rights Reserved | Powered by LiTaiTester Sitemap XML
Go to Top